Construction Log Report
Report Created by KitLog Pro
Printed:
6/21/2007
 9:41:57PM
40406
40313 N Candlewyck Ln
Van's Aircraft
RV-10
Kit Manufacturer:
Kit Model:
Kit Serial Number:
Anthem, AZ 85086
Deems Davis
Owner City/State/Zip:
Owner Address:
Owner Name:
Manual Reference #
Category
Date
Partner
Hours 
6/19/2007
Firewall Forward
 3.00
Sec FFPS-3
Began sorting out the remaining probes and sensors. Installed the Stainless steel firewall fixture from EPM. Attached all of the 
sensor harnesses to the JPi box, found out that the JPI documentation is wrog and shows a couple of harnesses in the wrong 
place, confirmed w a call to OP Tech. sorted which wires need to pass thru the firewall and routed them forward. I may have an 
interference with the JPI EIU and the Co-pilot MFD, i'll know in a couple of days. installed all of the CHT probes using John Cox's 
turbine high temp anti seize. I called BPE to find out where the Oil temp probe and the RPM sensor attach, The oil temp goes on 
the back of the Oil Filter adapter in a hole machined for an 5/8-18 fitting, the problem is that my Oil temp probe if 1/8 NPT """ I 
spent a fair amount of time looking for an adapter, and then found it easier to order a WESTACH sensor that has the 5/8-18 
fitting integral to it. will be here FRI. The RPM sensor goes on the Magneto vent that does NOT have a cap on it, doesn;t matter 
which mag. John Cox will be here Fri/Sat and i'm hoping he can help me figure a good way to tidy up the wires forward of the 
firewall.
CHT's inserted in each cyl
JPI engine monitor with appropriate wires run forward
Firewall  pass through
Page 1 of 1